Lifting for all lifting directions.
WLL for vertical lifting is marked on the eye.
In lateral lifting the load is 25% of the vertical lifting WLL.
The depth of the threaded hole has to be minimum:
d = diameter of the lifting eye thread
- 1*d for steel
- 1,25*d for cast iron
- 2*d for aluminum alloys
- 2,5*d for aluminum magnesium alloys
- Material: Steel
- Marking: According to standard, CE-marked
- Temperature range: -40 - +200°
- Finish: Painted, yellow
- Standard: EN 1677-1
- Safety factor: 4:1
- Grade: 8


Select a row from the table below, then click the add to quote button